KRASO Builder´s Convenience Box - wall - ESH
KRASO Builder´s Convenience Box - wall - ESH
Convenient, safe, securely attached to the network - single house connection for buildings with a basement for gas, water, electricity or telecommunication
+ Simple and safe single-house connection for new buildings and rehabilitation on buildings with a basement.
+ Flexible installation: Gas, water, electricity, telecommunication - including a suitable installation or mounting set.
+ Double installation also possible: Electricity and telecommunication!
+ DVGW-certified according VP 601: overall system is gas- and water pressure tight up to 1 bar!
+ For core hole DN 100 (99 - 103 mm). One for all: precast walls, in situ concrete walls, casings and core holes.
+ For wall thicknesses 160 - 500 mm.
+ Tight in waterproof concrete structures in stress class 1 (standing or occasionally pressing water).
+ External sealing element with flange according DIN 18533! Seal: 80 mm.
+ Radon tightness IAF tested - meets the requirements for radon precautionary areas according to FHRK leaflet MB 101! Resistant to methane gas!
+ Gas and odour-tight - high-quality according TA-Air!
+ Splited end plugs for easy installation!
+ Including extension set.
+ Simple and safe single-house connection for new buildings and rehabilitation on buildings with a basement.
+ Flexible installation: Gas, water, electricity, telecommunication - including a suitable installation or mounting set.
+ Double installation also possible: Electricity and telecommunication!
+ DVGW-certified according VP 601: overall system is gas- and water pressure tight up to 1 bar!
+ For core hole DN 100 (99 - 103 mm). One for all: precast walls, in situ concrete walls, casings and core holes.
+ For wall thicknesses 160 - 500 mm.
+ Tight in waterproof concrete structures in stress class 1 (standing or occasionally pressing water).
+ External sealing element with flange according DIN 18533! Seal: 80 mm.
+ Radon tightness IAF tested - meets the requirements for radon precautionary areas according to FHRK leaflet MB 101! Resistant to methane gas!
+ Gas and odour-tight - high-quality according TA-Air!
+ Splited end plugs for easy installation!
+ Including extension set.
+
DafStB waterproof concrete guidline: Stress class 1 + 2, DIN 18533 W1 -E and W2.1 -E
Info
Scope of supply:
KRASO Builder’s Convenience Box - wall - ESH including
• internal sealing element with pre-installed casing pipe incl. protective cover for the installation of supply lines like gas, water, electricity, telecommunication
- external sealing element
- installation instruction KRASO BKP - wall - ESH
- folding rule
• KRASO BKP - wall - ESH - extension set including
- double sleeve DN 75
- 2 x sealing ring
- lubricant
as wall as one of the following optionally available installation sets of BKP gas installation kits:
- KRASO BKP - Sealing Insert - electricity/water -
with steppless ring technology 26 - 50 mm or blind
- primary sealing + secondary sealing for electricity/water
- casing pipe end plugs consisting of
· end plug electricity/water - split -
· hose connection 80
- KRASO BKP - Sealing Insert - telecommunication -
clamping range: 5 - 13 mm, 3 x 7 - 13 mm, 13 - 21 mm
- primary sealing + secondary sealing for telecommunication
- casing pipe end plugs consisting of
· end plugs for telecommunication - split -
· hose connection 80
- KRASO BKP - Sealing Insert - electricity + telecommunication -
clamping range: electricity 25 - 36 mm / telecommunication
2 x 5 - 10 mm, 3 x 7 - 14 mm
- primary sealing + secondary sealing for electricity + telecommunication
- casing pipe end plugs consisting of
· end plugs for electricity + telecommunication
· hose connection 80
- tube of lubricant
• Schuck DN 25 consists of primary and secondary sealing as well as gas end plug
• RMA DN 25 consists of primary and secondary sealing as well as gas end plugKRASO Builder’s Convenience Box - wall - ESH including
• internal sealing element with pre-installed casing pipe incl. protective cover for the installation of supply lines like gas, water, electricity, telecommunication
- external sealing element
- installation instruction KRASO BKP - wall - ESH
- folding rule
• KRASO BKP - wall - ESH - extension set including
- double sleeve DN 75
- 2 x sealing ring
- lubricant
as wall as one of the following optionally available installation sets of BKP gas installation kits:
- KRASO BKP - Sealing Insert - electricity/water -
with steppless ring technology 26 - 50 mm or blind
- primary sealing + secondary sealing for electricity/water
- casing pipe end plugs consisting of
· end plug electricity/water - split -
· hose connection 80
- KRASO BKP - Sealing Insert - telecommunication -
clamping range: 5 - 13 mm, 3 x 7 - 13 mm, 13 - 21 mm
- primary sealing + secondary sealing for telecommunication
- casing pipe end plugs consisting of
· end plugs for telecommunication - split -
· hose connection 80
- KRASO BKP - Sealing Insert - electricity + telecommunication -
clamping range: electricity 25 - 36 mm / telecommunication
2 x 5 - 10 mm, 3 x 7 - 14 mm
- primary sealing + secondary sealing for electricity + telecommunication
- casing pipe end plugs consisting of
· end plugs for electricity + telecommunication
· hose connection 80
- tube of lubricant
• Schuck DN 25 consists of primary and secondary sealing as well as gas end plug
• Voigt DN 25 consists of primary and secondary sealing as well as gas end plug
• Voigt DN 32 consists of primary and secondary sealing as well as gas end plug
Downloads
Produktinformation
Datenblatt
Prüfzeugnis
Montageanleitung
-
Produktinfo_KRASO_bkp_wand_esh (3.43 MiB)
-
KRASO Technisches Datenblatt BKP - Wand - ESH_ (894.57 KiB)
-
Prüfbericht_KRASO_BKP_Wand_ESH (382.55 KiB)
-
Prüfbericht_KRASO_BKP_Dichteinsatz (605.72 KiB)
-
montageanleitung_kraso_bkp_wand_esh (2.87 MiB)
Type / Item |
KRASO BKP - wall - ESH |
Wall thickness from ... to ... |
160 - 500 mm |
Diameter casing or core hole min ... max ... |
99 - 103 mm |
Whole system length |
630 mm |
Length x width internal sealing element |
120 x 120 mm |
Seal width internal sealing element |
40 mm |
Diameter external sealing element with flange seal |
160 mm |
Seal width external sealing element with flange seal |
80 mm |
Internal diameter casing pipe |
68 mm |
External diameter casing pipe |
75 mm |