Willkommen beim KRASO Profi Chat

Unsere Experten freuen sich auf Ihre Fragen.
Mo.-Do.: 07:00 bis 17:00 Uhr
und Fr.: 07:00 bis 15:30 Uhr

KRASO WHATSAPP BUSINESS
Kontaktiere uns unter folgender Nummer:
Klicke auf die folgende Nummer, um uns zu kontaktieren:
+49 2872 95 35 888
KRASO Foil Clamping Flange Type FKF
for the sealing of media of all kinds of materials in front of a wall or in the core drilling, with foil flange 1,2 mm, according DIN 16937, oil- and bitumen resistant, surrounding approx. 15 cm, 30 mm seal | DIN 18533 W1 -E and W2.1 -E The revolution in terms of the integration of media lines into the sealing of larger areas+ Innovative: water pressure tight sealing of any even and stable cable with our KRASO Foil Clamping Flange Type FKF foil flange!+ Suitable for all external diameters of media lines and for all materials! + We can individually customise the type of sealing sheets or foils: e.g. PVC, EPDM, FPO, RESITRIX®, PP, PE, KRASO-Fol, PYE-PV 200 S5 etc. + Torque Control Nut KRASO DKM: integrated torque limiter - no torque wrench required!+ Metal components made of non-corrosive stainless steel V2A. + For new buildings and rehabilitation! Various designs for almost every situation! + Simple and fast mounting! + MPA-tested: water pressure tight up to 2,5 bar!+ Tested according to FHRK testing specification GE 101!+ DIN 18533 W1 -E and W2.1 -E
KRASO Foil Clamping Flange Type FKF DD/GR
for the sealing of media of all kinds of materials in front of a wall or in the core drilling, with foil flange 1,2 mm, according to DIN 16937, oil- and bitumen resistant, surrounding approx. 15 cm, 40 mm specially soft seal, central pressure distribution plate for even pressure distribution with corrugated media pipes, against pressing water up to 1 bar, Torque Control Nut KRASO DKM, non-corrosive stainless steel V2A | DIN 18533 W1 -E and W2.1 -E The revolution in terms of the integration of media lines into the sealing of larger areas + Innovative: water pressure tight sealing of any even and stable cable with our KRASO Foil Clamping Flange Type FKF foil flange!+ Suitable for all external diameters of media lines and for all materials!+ We can individually customise the type of sealing sheets or foils: e.g. PVC, EPDM, FPO, RESITRIX®, PP, PE, KRASO-Fol, PYE-PV 200 S5 etc.+ Torque Control Nut KRASO DKM: integrated torque limiter - no torque wrench required!+ Metal components made of non-corrosive stainless steel V2A.+ For new buildings and rehabilitation! Various designs for almost every situation!+ Simple and fast mounting!+ MPA-tested: water pressure tight up to 2,5 bar! + Tested according to FHRK testing specification GE 101!+ DIN 18533 W1 -E and W2.1 -E
KRASO Foil Clamping Flange Type FKF Universal
for the sealing of media of all kinds of materials in front of a wall or in the ore drilling, with foil flange 1,2 mm, according DIN 16937, oil- and bitumen resistant, surrounding approx. 15 cm, 40 mm seal, against pressing water up to 1,5 bar, Torque Control Nut KRASO DKM, non-corrosive stainless steel V2A | DIN 18533 W1 -E and W2.1 -E The revolution in terms of the integration of media lines into the sealing of larger areas+ Innovative:  water pressure tight sealing of any even and stable pipe or cable with our KRASO Foil Clamping Flange FKF foil flange+ Suitable for all external diameters of media lines and for all materials! + We can individually customise the type of sealing sheets or foils: e.g. PVC, EPDM, FPO, RESITRIX®, PP, PE, KRASO-Fol, PYE-PV 200 S5 etc . + Torque Control Nut KRASO DKM: integrated torque limiter - no torque wrench required!+ Metal components made of non-corrosive stainless steel V2A. + For new building and rehabilitation! Various designs for almost every situation! + Simple and fast mounting! + MPA-tested: water pressure tight up to 2,5 bar! + Tested according to FHRK testing specification GE 101!+ DIN 18533 W1 -E and W2.1 -E
KRASO Casing Type FL/ZA
fixed-loose flange for dowel-fixing, with casing, for installation of media pipes using a sealing insert (not included in the scope of supply), for buildings with exterior sealing ("black tank") according to DIN 18533. Available in non-corrosive stainless steel V2A or electrogalvanised, each with or without special coating ID = InternalDiameter | DIN 18533 W2.1 -E and W2.2 -EFixed-loose flange for dowel-fixing or for concreting and as sealing insert+ For buildings with exterior sealing ("black tank"): according DIN 18533 ( "sealing of below-ground structural elements").+ Each design available as separate types for pressing and non-pressing water+ Available in non-corrosive stainless steel V2A or V4A and in electrogalvanised steel+ Upon request available with special coating for buildings with thick coating (e.g. KMB)! + DIN 18533: water exposure class W2.1 -E and W2.2 -E (“medium impact of pressing water“ (water column ≤ 3 metres)“ / „high impact of pressing water (water column ≥ 3 metres)“)
KRASO Casing Type FL/ZE
fixed-loose flange for concreting, with casing, for installation of media pipes using a sealing insert (not included in the scope of supply), for buildings with exterior sealing ("black tank") against pressing / non-pressing water according to DIN 18533. Available in non-corrosive stainless steel V2A or electrogalvanised with plastic casing, each with or without special coating ID = InternalDiameter | DIN 18533 W2.1 -E and W2.2 -E Fixed-loose flange for dowel-fixing or for concreting and as sealing insert + For buildings with exterior sealing (“black tank“): according to DIN 18533 (“sealing of below-ground structural elements“) + Each design available as separate types for pressing and non-pressing water + Available in non-corrosive stainless steel V2A or V4A and in electrogalvanised steel + Upon request available with special coating for buildings with thick coating (e.g. KMB)! + DIN 18533: water exposure classes W2.1 -E and W2.2 -E (“medium impact of pressing water“ - water column ≤ 3 metres / „high impact of pressing water" - water column ≥ 3 metres)
KRASO Sealing Insert Type FL
fixed-loose flange with KRASO Sealing Insert, for installation of media pipes, for buildings with exterior sealing ("black tank") according to DIN 18533. Available in non-corrosive stainless steel V2A or electrogalvanised, each with or without special coating, Torque Control Nut KRASO DKM | DIN 18533 W2.1 -E and W2.1 -EFixed-loose flange for dowel-fixing or for concreting and as sealing insert  + For buildings with exterior sealing (“black tank“): according to DIN 18533 (“sealing of below-ground structural elements“) + Each design available as separate types for pressing and non-pressing water + Available in non-corrosive stainless steel V2A or V4A and in electrogalvanised steel + Upon request available with special coating for buildings with thick coating (e.g. KMB)! + DIN 18533: water exposure classes W2.1 -E and W2.2 -E (“medium impact of pressing water“ - water column ≤ 3 metres / „high impact of pressing water" - water column ≥ 3 metres)
KRASO PU 50
high-quality, permanently elastic and strong PU-sealant, also suitable on moist surface, recommended for all products with KRASO Foil Flange, colour black